top of page

MK2B Normally Open Direct Acting Solenoid Valve

QUEEN SOLENOID VALVES

Discription

  • Suitable for air, inert gases, vacuum(10^-4 Torr).

  • Direct acting solenoid valves, normally open.

  • Can be mounted in vertical and horizontal position.

  • Operates directly without requiring pressure differential.

  • Connection size: PT 3/8".

  • The "M17" marking indicates a waterproof coil with an IP65 rating.

Specifications

Model

​​​​​​

 (1) MK2B-0545-10C (M17) 

​(2) MK2B-1230-10C (M17)

​(3) MK2B-2520-10C (M17)

​(4) MK2B-4016-10C (M17)

Action mode

Normally open

Voltage

AC 24, 110, 220, 380V 50/60 Hz

DC 12, 24V​

Media

Air, vaccum, gas

Fluid temp.

-5~90°C

Fluid viscosity

-

Pressure range​​​

(1) Air :  5 kgf/cm2 

(2) Air : 12 kgf/cm2​​

(3) Air : 25 kgf/cm2

(4) Air : 40 kgf/cm2

Connection size

PT 3/8"

Orifice

 

(1) 4.5 mm

(2)    3 mm​

(3)    2 mm

(4) 1.6 mm​

Cv valve

(1) 0.42

(2)   0.3​

(3) 0.18

(4) 0.11​

Direction

Vertical / Horizontal

Valve material

BSBF

Coil type

Iron case coil: IP54

​Waterproof coil: IP65

Cautions

1. Before installation, please check whether the solenoid valve voltage is consistent with the power supply voltage.

  • AC voltage tolerance: ±10%

  • DC voltage tolerance: ±1%

2. If there are unclean impurities in the fluid, a filter should be installed to avoid reducing the service life and hindering the operation of the solenoid valve.

3. Please install the solenoid valve in the direction of the fluid.

4. Not suitable for freezing fluids.

Certificate

- CE