top of page

MK2A Normally Open Direct Acting Solenoid Valve

QUEEN SOLENOID VALVES

Discription

  • Suitable for air, inert gases, vacuum (10^-4 Torr), water, kerosene oil, and oil (Below 50 cst).

  • Normally open direct acting solenoid valve.

  • Can be mounted in vertical and horizontal position.

  • Operates directly without requiring pressure differential.

  • Connection size: PT 1/4", PT 3/8".

Specifications

Model

​​​​

 (1) MK2A-0530-8(10)C 

​(2) MK2A-0820-8(10)C

(3) MK2A-1216-8(10)C

Action mode

Normally open

Voltage

AC 24, 110, 220, 380V 50/60Hz

DC 12, 24V​

Media

Air, gas, vaccum, water, oil

Fluid temp.

-5~90°C

Fluid viscosity

Oil : 50cst or less

Pressure range

(1) Air : 4  water, oil : 3 kgf/cm2  

(2) Air : 8  water, oil : 6 kgf/cm2  ​

(3) Air : 12 water, oil : 8 kgf/cm2 

Connection size

PT 1/4"

PT 3/8"

Orifice

(1)   3 mm

(2)   2 mm​

(3)1.6 mm​

Cv valve

(1)   0.25

(2)   0.15

(3) 0.095

Direction

Vertical / Horizontal

Valve material

BSBF (SUS 303L on request)

Coil type

Iron case coil: IP54

Cautions

1. Before installation, please check whether the solenoid valve voltage is consistent with the power supply voltage.

  • AC voltage tolerance: ±10%

  • DC voltage tolerance: ±1%

2. If there are unclean impurities in the fluid, a filter should be installed to avoid reducing the service life and hindering the operation of the solenoid valve.

3. Please install the solenoid valve in the direction of the fluid.

4. Not suitable for freezing fluids.

Certificate

- CE