top of page

MD15C~50C Normally Open SUS Diaphragm Solenoid Valve

QUEEN SOLENOID VALVES

Discription

  • Suitable for air, inert gases, vacuum (10^-4 Torr), water, kerosene oil, and oil (Below 50 cst).

  • Pilot operated, pressure range from 0.3kg*f/cm² to 10kg*f/cm².

  • Can be mounted in vertical and horizontal position.

  • The "M17" marking indicates a waterproof coil with an IP65 rating.

  • The diaphragm can be selected from NBR, EPDM, or Viton.

  • Material designation :

  - SCS13 : Stainless Steel 304

  - SCS14 : Stainless Steel 316

Specifications

Model

​​​​​​

​​

​​​

 ​(1) MD-15C-SCS13,14 (M17) 

​(2) MD-20C-SCS13,14 (M17)

​(3) MD-25C-SCS13,14 (M17)

(4) MD-32C-SCS13,14 (M17)

​(5) MD-40C-SCS13,14 (M17)

(6) MD-50C-SCS13,14 (M17)

Action mode

Normally open

Voltage

AC 24, 110, 220, 380V 50/60 Hz

DC 12, 24V​

Media

Air, vaccum, gas, water, oil

Fluid temp.

-5~90°C

Fluid viscosity

Oil : 50 cst or less

Pressure range

Air, water, gas : 0.3~10 kgf/cm2 

Oil : 0.3~7 kgf/cm2 

Connection size​​​

​​​

​(1) PT 1/2"    

​(2) PT 3/4"    

​(3) PT 1"       

(4) PT 1-1/4"

​(5) PT 1-1/2"

(6) PT 2"       

Orifice

 

 

(1) 16 mm​

(2) 23 mm

(3) 28 mm​

(4) 32 mm​​

(5) 40 mm​​

(6) 50 mm​

Cv valve

​​​​

​​

​​​

 

(1)   3.7

(2)   6.3

(3)   8.0

(4) 13.0

(5) 20.3

(6)    32

Direction

Vertical / Horizontal

Valve material

S.S 304

S.S 316

Seal material

NBR

EPDM

​VITON

Coil type

Iron case coil: IP54

​Waterproof coil: IP65

Seal Material Characteristics

• NBR

Temperature : -5~80°C

∙ Pros : Economical, widely used, with good oil and wear resistance.

∙ Cons : Unsuitable for polar solvents like nitro compounds, ozone, and ketones.

• EPDM

Temperature : -10~130°C

∙ Pros : Resistance to polar solvents (alcohols, ketones, ethylene glycol) and mild acids/bases.

∙ Cons : Not suitable for gasoline, mineral oil, and aromatic hydrocarbons.

• VITON (FPM/FKM)

Temperature : -10~120°C

∙ Pros : Stable, aging-resistant, and resistant to most oils and solvents.

∙ Cons : Costly, not recommended for ketones, esters, or nitro compounds.

Cautions

1. Before installation, please check whether the solenoid valve voltage is consistent with the power supply voltage.

  • AC voltage tolerance: ±10%

  • DC voltage tolerance: ±1%

2. If there are unclean impurities in the fluid, a filter should be installed to avoid reducing the service life and hindering the operation of the solenoid valve.

3. Please install the solenoid valve in the direction of the fluid.

4. Pilot-operated solenoid valves require a minimum pressure to open.

5. Not suitable for freezing fluids.

Certificate

- CE

bottom of page