top of page

MD10~50 Diaphragm Type Solenoid Valve

QUEEN SOLENOID VALVES

Discription

  • Suitable for air, inert gases, vacuum (10^-4 Torr), water, kerosene oil, and oil (Below 50 cst).

  • Semi direct-acting diaphragm type solenoid valve, operating pressure range from vacuum (10^-4 Torr) up to 10 kgf/cm², quick acting.

  • Can be mounted in vertical and horizontal position.

  • The diaphragm can be selected from NBR, EPDM or VITON.

  • Material designation :

  ∙ SCS13 : Stainless Steel 304

  ∙ SCS14 : Stainless Steel 316

Specifications

Model​​​​​

​​

(1) MD-10WAG                   

(2) MD-15WAG(SCS13, 14)

(3) MD-20WAG(SCS13, 14)

(4) MD-25WAG(SCS13, 14)

(5) MD-32WAG(SCS13, 14)

(6) MD-40WAG(SCS13, 14)

(7) MD-50WAG(SCS13, 14)

Action mode

Normally closed

Voltage

AC 24, 110, 220, 380V 50/60Hz

DC 12, 24V​

Media

Air, gas, vaccum, water, oil

Fluid temp.

-5~90°C

Fluid viscosity

Oil : 50 cst or less

Pressure range

Air, water, gas : 0~10 kgf/cm²

Oil : 0~7 kgf/cm²

Connection size​​​

 

(1) PT 3/8"   

(2) PT 1/2"   

(3) PT 3/4"   

(4) PT 1"    ​   

(5) PT 1-1/4"

(6) PT 1-1/2"

(7) PT 2"       

Orifice​​​​

(1) 16 mm

(2) 16 mm

(3) 23 mm

(4) 28 mm

(5) 32 mm

(6) 40 mm

(7) 50 mm

Cv valve

(1)   3.7

(2)   3.7

(3)   6.3

(4)   8.0

(5) 13.0

(6) 20.3

(7)    32

Direction

Vertical / Horizontal

Valve material

3/8"~1"(C3771BE)

1-1/4"~2"(BC6)

1/2"~2"(SCS13/SCS14)

Seal material

​​

​​

NBR

EPDM

VITON

Coil type​​​​

Iron case coil: IP54

Order Information

Seal Material Characteristics

• NBR

Temperature : -5~80°C

∙ Pros : Economical, widely used, with good oil and wear resistance.

∙ Cons : Unsuitable for polar solvents like nitro compounds, ozone, and ketones.

• EPDM

Temperature : -10~130°C

∙ Pros : Resistance to polar solvents (alcohols, ketones, ethylene glycol) and mild acids/bases.

∙ Cons : Not suitable for gasoline, mineral oil, and aromatic hydrocarbons.

• VITON (FPM/FKM)

Temperature : -10~120°C

∙ Pros : Stable, aging-resistant, and resistant to most oils and solvents.

∙ Cons : Costly, not recommended for ketones, esters, or nitro compounds.

Cautions

  • Before installation, please check whether the solenoid valve voltage is consistent with the power supply voltage.
    AC voltage tolerance: ±10%
    DC voltage tolerance: ±1%

  • If there are unclean impurities in the fluid, a filter should be installed to avoid reducing the service life and hindering the operation of the solenoid valve.

  • Please install the solenoid valve in the direction of the fluid.

  • Not suitable for frozen fluids

Certificate

  • CE

bottom of page