MA-P10~15 Pilot-operated Diaphragm Solenoid Valve
QUEEN SOLENOID VALVES
Discription
-
Pilot Operated solenoid valve with large flow capacity and low power consumption, only 5 watts.
-
Suitable for air, inert gases, water, kerosene, and light oils (below 50 cst).
-
Operating pressure range from 0.1 kgf/cm² to 16 kgf/cm², offering fast action and excellent durability.
-
Simple and convenient piping, suitable for both vertical and horizontal pipe connections without restrictions.
-
The "M10" marking indicates a waterproof coil with an IP65 protection rating.
-
The solenoid valve diaphragm is available in NBR, EPDM, or VITON materials.
Specifications
Model
(1) MA-P10-M10
(2) MA-P15-M10
Action mode
Normally closed
Voltage
AC 24, 110, 220, 380V 50/60Hz
DC 12, 24V
Media
Air, gas, water, oil
Fluid temp.
-5~90°C
Fluid viscosity
Oil : 50 cst or less
Pressure range
Air : 0.1~16 kgf/cm2
Liquid : 0.1~15 kgf/cm2
Connection size
(1) PT 3/8"
(2) PT 1/2"
Orifice
12 mm
Cv valve
2.6
Direction
Vertical / Horizontal
Valve material
BSBF
Seal material
NBR
EPDM
VITON
Coil type
Waterproof coil: IP65
Seal Material Characteristics
• NBR
∙ Temperature : -5~80°C
∙ Pros : Economical, widely used, with good oil and wear resistance.
∙ Cons : Unsuitable for polar solvents like nitro compounds, ozone, and ketones.
• EPDM
∙ Temperature : -10~130°C
∙ Pros : Resistance to polar solvents (alcohols, ketones, ethylene glycol) and mild acids/bases.
∙ Cons : Not suitable for gasoline, mineral oil, and aromatic hydrocarbons.
• VITON (FPM/FKM)
∙ Temperature : -10~120°C
∙ Pros : Stable, aging-resistant, and resistant to most oils and solvents.
∙ Cons : Costly, not recommended for ketones, esters, or nitro compounds.
Cautions
1. Before installation, please check whether the solenoid valve voltage is consistent with the power supply voltage.
AC voltage tolerance: ±10%
DC voltage tolerance: ±1%
2. If there are unclean impurities in the fluid, a filter should be installed to avoid reducing the service life and hindering the operation of the solenoid valve.
3. Please install the solenoid valve in the direction of the fluid.
4. The pilot solenoid valve needs a basic pressure to open
5. Not suitable for frozen fluids